Aspen Gas Heater U115rs User Manual
Categories |
- Appliance manuals and free pdf instructions. Find the user manual you need for your home appliance products and more at ManualsOnline.
- Our sales and customer support organization to position Aspen for the next level of growth. Aspen Background: Why Aspen: ASPEN MANUFACTURING. 373 ATASCOCITA ROAD. HUMBLE, TEXAS 77396 PHONE 800.423.9007. FAX 281.441.6510 EMAIL INFO@ASPENMFG.COM. WEB WWW.ASPENMFG.COM.
Gas Heater (21) Water Heater (2) American Water Heater Electric Heater User Manuals. American Water Heater 25 Gallon Tiny Titan Electric Water Heater E1E25US015V user manual Add to Favourites PRINTED 0707 85833-000 Keep this manual in the pocKet on heater for future reference when ever maintenance adjustment or service is required.
|
Heaters | Heaters | Heaters | Gas Heaters | Heaters | Heaters | Heaters |
Back to Modine Heaters Pricing Page
We stock many parts for Modine gas heaters and can have any other Modine part shipped to you in 2 to 3 days. To accurately identify your Modine heater part, we will need the following information: | ||
Click here to locate power & control codes on the heater plate |
| PD, PAE, PA Main Parts Diagram |
The Modine heater information can typically be found on the back of your Modine heater (see example above). The more details you can provide, the faster we can respond to your parts request. Please e-mail Modine heater information to. | ||
Modine's collection of installation manuals and wiring diagrams for discontinued models like the PA, PAE, PD, PV heaters and more are available here. |
All replacement Modine burner assemblies are stainless steel. The replaced model # listed below is Modine's model # for the standard aluminized burner installed on the heater. Modine only sells replacement heater burners in stainless steel. |
(replaces 3H33073-2) | PA50, PD50. PDP50 |
(replaces 3H33073-3) | PA75, PAE50, PV50, PD75, PDP75 |
(replaces 3H33073-14) | PV75 |
(replaces 3H33073-4) | PA105, PD100, PDP100 |
(replaces 3H33073-16) | PD125, PDP125 |
(replaces 3H33073-5) | PA130, PA150, PAE100, PAE125, PV100, PV125, PD150, PDP150 |
(replaces 3H33073-6) | PA170, PA175, PAE145, PV145, PD175, PDP175 |
(replaces 3H33073-7) | PA200, PA225, PAE175, PAE200, PV175, PV200, PD200, PD250, PDP200, PDP250 |
(replaces 3H33073-9) | PA300, PAE225, PAE250, PV250, PD300, PDP300 |
(replaces 3H33073-10) | PA350, PAE300, PAE350, PV300, PV350, PD350, PDP350 |
(replaces 3H33073-11) | PA400, PAE400, PV400, PD400, PDP400 |
Thermocouple comes in two lengths: 36' (Modine part # 5H69336-6) for standing pilot gas heaters 100,000 BTUs or less and 48' (Modine part # 5H69336-7) for all larger Modine standing pilot heaters. |
Universal standing pilot assembly includes tubing, pilot burner, mounting bracket, instructions, & pilot orifices for LP and NG. Modine Part # 3H37454-2 (Works with standing pilot Modine PD, PAE, & PA heaters) Old part # 3H34030-10 |
Manual reset switch. Modine Part # 5H73057 (Works with most Modine PD, PDP, PAE, & PA heaters built after 1986) |
Temperature limit control with auto reset. Modine part # 5H73593 (Works with most Modine gas unit heaters) |
Some older PA models use this 3 wire limit switch which also runs the fan instead of a timer. Modine part # 5H68074 (Works with older PA Modine gas unit heaters) |
Delays main heater fan when coming on and shutting off. Modine part # 5H73035 (Works with most PD, PAE, & PA heaters) |
Delays main heater fan when coming on and shutting off. Modine part # 5H71675 (Works with most PDP & PV heaters) |
Converts line 120v to low 24v for heater controls. Modine Part # 5H71956-1 (Works with most Modine PD, PDP, PAE, & PA heaters built after 1986) |
Replacement terminal board for wiring 24v controls to the heater. Board mounts to junction box on back of heater. Modine Part # 5H71955 (Works with most Modine heaters with 24v controls) |
All stocked Modine fan / blower motors are listed bleow.They are all 120v motors. Fan motors only come with what is shown in the picture. If you do not see the Modine motor you need below, email the heater model # and serial # to Note: If you have a PA model made before 1980, the part listed below may not work with your heater. If the last 2 digits on your PA heater's serial # are NOT 80 or higher, email your heater model # and serial # to Part #29 on heater diagram. |
PA30, PA50, PA75, PAE30, PAE50, PD30, PD50, PV30, PV50, PDP30, PDP50, PAH40, PAH55 | |
PAE75, PAE100, PV75, PV100 | |
PD75, PD100, PDP75, PDP100 | |
PD125, PD150, PDP125, PDP150 | |
PA105, PA130, PAE125, PV125 | |
9F30095 | PA145 thru PA225, PAE145 thru PAE225, PV145 thru PV200, PD175, PD200, PDP175, PDP200, PAH130, PAH180, PSH130, PSH170 |
PA250, PA300, PAE250, PAE300, PV250, PV300, PD250, PDP250, PAH240, PSH225 | |
PA350, PA400, PD300, PDP300, PAH300, PAH360, PSH280, PSH340 | |
PA400, PAE350, PAE400, PV350, PV400, PD350, PD400, PDP350, PDP400, PAH360, PTS400, PTC400 |
This Honeywell gas valve is used in Modine PD, PAE, and PA 24 volt standing pilot heaters up to 200,000 BTU input. Comes setup for natural gas and includes kit to convert to propane. Replaces Modine part #s 5H71923 & 5H71924. |
Aspen Gas Heater U115rs User Manual Free
This Honeywell gas valve is used in Modine PD, PAE, and PA 24 volt standing pilot heaters 250,000 to 400,000 BTU input in propane & 250,000 input in natural gas. Comes setup for natural gas and includes kit to convert to propane. Replaces Modine part #s 5H73100-2 & 5H73115-2. |
This Honeywell gas valve is used in Modine PD, PAE, and PA 24 volt standing pilot heaters 300,000 to 400,000 BTU input in natural gas. Comes setup for natural gas and includes kit to convert to propane. Replaces Modine part # 5H72591-3. Can be used with larger propane models as well. |
These kits convert Modine PAE, PV, PD & PDP 30-400 heaters from natural gas (NG) to propane (LP). Each comes with main burner & pilot orifices, air shutters, a spring kit for the gas valve on your heater, conversion sticker, and installation instructions. You will need to specify the brand of gas valve on your heater to receive the proper conversion kit. Pictures are shown below. |
For other Modine conversion kits, emailand include your heater model #, power code, control code, and the brand and model # of gas valve on the heater (see pictures below for help). | |||
Model # starts with V | Model # starts with 7 | Model # starts with 3 |
Modine PDP Gas Heaters Modine PAE Gas Heaters Modine PV Gas Heaters |
Aspen Gas Heater U115rs User Manual Guide
For other Modine conversion kits, emailand include your heater model #, power code, control code, and the brand and model # of gas valve on the heater |
Back to Modine Heaters Pricing Page
Watering Electrical Plastic PVC Books Containers Other
ACF Greenhouses
380 Greenhouse Drive
Buffalo Junction, VA 24529
434-374-2706 Phone, 434-374-2055 Fax
888-888-9050 Toll Free
Copyright Aarons Creek Farms, Inc. All Rights Reserved.