Kemppi Minarctig Evo 200 User Manual
- Kemppi Minarcmig Evo 200 User Manual
- Kemppi Minarctig Evo 200 User Manual Free
- Kemppi Minarctig Evo 200 User Manual 2016
- Kemppi Minarctig Evo 200 User Manual 2017
- Kemppi Minarctig Evo 200 Mlp Manual
MinarcMig Evo 200 Support for MinarcMig Evo 200. Technical specifications in the user manual has the recommended model and size. Kemppi employs over 800. MinarcMig Evo 200 AU Kemppi K5 MIG welder for mobile, adaptive welding in automatic and manual mode. Mains plug suitable for AU/NZ markets. The delivery package includes a MIG welding gun, cables, gas hose and shoulder strap. MinarcMig Evo 170 Kemppi K3 MIG welder for mobile welding in manual mode with separate controls for voltage and wire.
EN
5.
MinarcTig Evo 200, 200MLP. EN OPERATING MANUAL. Instructions in the manual. For more information on Kemppi products, contact Kemppi Oy, consult an authorised Kemppi dealer, or visit the Kemppi web site at www.kemppi.com. The specifications presented in this manual are subject to change without prior notice. Kemppi FastMig KM400 Manuals & User Guides. User Manuals, Guides and Specifications for your Kemppi FastMig KM400 Welding System. Database contains 3 Kemppi FastMig KM400 Manuals (available for free online viewing or downloading in PDF): Operating manual. The MinarcMig Evo 170 is set manually, with separate control for wire feed speed and voltage. MinarcMig Evo 200 machine has both an automatic and manual operation mode. In the automatic mode, you must first select the filler wire material after which the welding voltage. Kemppi MinarcMig Evo 200 An adaptive tool for the mobile welder. MinarcMig Evo 200 packs huge MIG/MAG welding capacity and quality into it’s portable, compact size. With 200 A output, delivering it’s welding power at 35% duty cycle from a 16 A, 1-phase mains supply. MinarcMig Evo 200 delivers premium results wherever your work takes you.
errOr CODes
The machine always checks its operation automatically during start-up and reports any
failures detected. If failures are detected during start-up, they are shown as error codes on the
Kemppi Minarcmig Evo 200 User Manual
control panel display.
error 2: power source undervoltage
The device has stopped because it has detected a mains undervoltage that disturbs welding.
Check the quality of the supply network.
error 3: power source overvoltage
The machine has stopped the welding because it has detected momentary voltage spikes or
continuous overvoltage dangerous to the machine in the electric network. Check the quality
of the supply network.
error 4: power source overheating
The power source has overheated. The cause may be one of the following:
• The power source has been used for a long time at maximum power.
• The circulation of cooling air to the power source is blocked.
• The cooling system has experienced a failure.
Remove any obstacle to air circulation, and wait until the power source fan has cooled down
the machine.
Other error codes:
The machine can show codes not listed here. In the event of an unlisted code appearing,
contact an authorised Kemppi service agent and report the error code shown.
5.1 troubleshooting
Problem
Cause
The main switch indicator will not
light up.
Kemppi Minarctig Evo 200 User Manual Free
• No electricity connected to the machine
• Check the mains supply fuses.
• Check the mains cable and plug.
Poor welding results.
Several factors affect the welding quality.
• Ensure that the welding current selected is adequate for the selected electrode type
and size.
• Ensure the cable connections are correct and secure.
• Ensure the process selection is correct.
• Check that the earth return clamp connection area is clean and that the cable and
clamp is not damaged.
• For TIG welding, check that the shielding gas flow is switched on and set correctly.
Poor ignition and arc quality in TIG welding may be a result of a poorly prepared
tungsten electrode. Always maintain and grind a point on the TIG torch electrode tip
before welding.
Overheating indicator is illuminated. Normally, this indicates that the device has reached its maximum designed operating
temperature. The thermostat has become active, switching the welding power off.
Allow the unit to cool and the machine will soon automatically reset and allow
welding to re-start.
• Ensure that cooling air has unrestricted flow.
• If the machine’s duty cycle has been exceeded, wait for indicator to turn off.
In certain circumstances, this light may also indicate irregularity in the supply voltage.
Too low or high supply voltage.
If the machine’s malfunction is not eliminated with the above measures, contact Kemppi
service.